TIM 2-2413

TIM 2-2413

  • 厂商:

    TRACOPOWER

  • 封装:

    DIP7 模块

  • 描述:

    隔离模块 直流转换器 1 输出 15V 134mA 18V - 36V 输入

  • 数据手册
  • 价格&库存
TIM 2-2413 数据手册
DC/DC Medical Converter • • Compact DIP-16-package • Certification according to IEC/EN/ES 60601-1 3rd edition for 2xMOPP and operation up to 5000 m altitude TIM 2 Series, 2 Watt I/O isolation 5000 VAC rated for 250 VAC working voltage • • Low leakage current < 2 µA • 5-year product warranty Extended operating temperature range –40°C to 95°C. ES 60601-1 IEC 60601-1 UL 62368-1 IEC 62368-1 The TIM 2 series is a range of 2 Watt DC/DC converters in compact DIP-16 package with reinforced isolation of 5000 VAC for medical applications. With a low leakage current of less than 2 µA the converters are predestined to insulate electrical equipment from the applied parts to patient (BF classification). The models are approved to IEC/EN/ES 60601-1 3rd ed. for 2xMOPP up to an altitude of 5000 m and come along with an ISO 14971 risk management file. Models Order Code Input Voltage Range TIM 2-0910 TIM 2-0911 TIM 2-0919 TIM 2-0912 TIM 2-0913 TIM 2-0915 TIM 2-0922 TIM 2-0923 TIM 2-1210 TIM 2-1211 TIM 2-1219 TIM 2-1212 TIM 2-1213 TIM 2-1215 TIM 2-1222 TIM 2-1223 TIM 2-2410 TIM 2-2411 TIM 2-2419 TIM 2-2412 TIM 2-2413 TIM 2-2415 TIM 2-2422 TIM 2-2423 TIM 2-4810 TIM 2-4811 TIM 2-4819 TIM 2-4812 TIM 2-4813 TIM 2-4815 TIM 2-4822 TIM 2-4823 www.tracopower.com 4.5 - 12 VDC (9 VDC nom.) 9 - 18 VDC (12 VDC nom.) 18 - 36 VDC (24 VDC nom.) 36 - 75 VDC (48 VDC nom.) Output 1 Output 2 Vnom Imax 3.3 VDC 5 VDC 9 VDC 12 VDC 15 VDC 24 VDC +12 VDC +15 VDC 3.3 VDC 5 VDC 9 VDC 12 VDC 15 VDC 24 VDC +12 VDC +15 VDC 3.3 VDC 5 VDC 9 VDC 12 VDC 15 VDC 24 VDC +12 VDC +15 VDC 3.3 VDC 5 VDC 9 VDC 12 VDC 15 VDC 24 VDC +12 VDC +15 VDC 600 mA 400 mA 222 mA 167 mA 134 mA 83 mA 83 mA 67 mA 600 mA 400 mA 222 mA 167 mA 134 mA 83 mA 83 mA 67 mA 600 mA 400 mA 222 mA 167 mA 134 mA 83 mA 83 mA 67 mA 600 mA 400 mA 222 mA 167 mA 134 mA 83 mA 83 mA 67 mA November 15, 2023 Vnom Efficiency Imax –12 VDC –15 VDC 83 mA 67 mA –12 VDC –15 VDC 83 mA 67 mA –12 VDC –15 VDC 83 mA 67 mA –12 VDC –15 VDC 83 mA 67 mA typ. 75 % 78 % 78 % 82 % 82 % 82 % 82 % 80 % 76 % 78 % 79 % 82 % 82 % 81 % 81 % 81 % 76 % 79 % 80 % 81 % 81 % 81 % 81 % 81 % 76 % 78 % 79 % 80 % 82 % 81 % 81 % 81 % Page 1 / 5 TIM 2 Series, 2 Watt Input Specifications Input Current - At no load 9 Vin models: 12 Vin models: 24 Vin models: 48 Vin models: 9 Vin models: 12 Vin models: 24 Vin models: 48 Vin models: 9 Vin models: 12 Vin models: 24 Vin models: 48 Vin models: 9 Vin models: 12 Vin models: 24 Vin models: 48 Vin models: Surge Voltage Under Voltage Lockout Recommended Input Fuse Input Filter 80 mA typ. 40 mA typ. 25 mA typ. 12 mA typ. 15 VDC max. (1 s max.) 25 VDC max. (1 s max.) 50 VDC max. (1 s max.) 100 VDC max. (1 s max.) 2 VDC min. / 3 VDC typ. / 4 VDC max. 6 VDC min. / 7 VDC typ. / 8 VDC max. 13 VDC min. / 15 VDC typ. / 17 VDC max. 29 VDC min. / 32 VDC typ. / 35 VDC max. 1'000 mA (slow blow) 500 mA (slow blow) 315 mA (slow blow) 160 mA (slow blow) (The need of an external fuse has to be assessed in the final application.) Internal Capacitor Output Specifications Voltage Set Accuracy Regulation - Input Variation (Vmin - Vmax) - Load Variation (10 - 90%) Ripple and Noise Capacitive Load - Cross Regulation (25% / 100% asym. load) - 20 MHz Bandwidth - single output - dual output ±1% max. 0.2% max. 0.2% max. 0.5% max. 0.8% max. (Output 1) 0.8% max. (Output 2) dual output models: 5% max. single output models: dual output models: single output models: dual output models: 3.3 Vout models: 5 Vout models: 9 Vout models: 12 Vout models: 15 Vout models: 24 Vout models: 12 / -12 Vout models: 15 / -15 Vout models: Minimum Load Temperature Coefficient Start-up Time Short Circuit Protection Overload Protection Overvoltage Protection Transient Response - Response Time 50 mVp-p typ. 1'000 µF max. 1'000 µF max. 430 µF max. 220 µF max. 170 µF max. 100 µF max. 170 / 170 µF max. 100 / 100 µF max. Not required ±0.02 %/K max. 10 ms typ. / 20 ms max. Continuous, Automatic recovery Foldback Mode 104 - 197% of Vout nom. (depending on model) 4 - 6.5 VDC (3.3 Vout models) 6 - 8 VDC (5 Vout models) 10 - 14 VDC (9 Vout models) 13 - 19 VDC (12 Vout models) 16 - 22 VDC (15 Vout models) 25 - 35 VDC (24 Vout models) 500 µs typ. (25% Load Step) All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com November 15, 2023 Page 2 / 5 TIM 2 Series, 2 Watt Safety Specifications Standards EN 62368-1 IEC 62368-1 UL 62368-1 EN 60601-1 IEC 60601-1 ANSI/AAMI ES 60601-1 2 x MOPP (Means Of Patient Protection) www.tracopower.com/overview/tim2 PD 2 - IT / Multimedia Equipment - Medical Equipment - Certification Documents Pollution Degree EMC Specifications EMI Emissions - Conducted Emissions - Radiated Emissions External filter proposal: EMS Immunity - Electrostatic Discharge Air: Contact: - RF Electromagnetic Field - EFT (Burst) / Surge Ext. input component: - Conducted RF Disturbances - PF Magnetic Field Continuous: 1 s: EN 60601-1-2 edition 4 (Medical Devices) EN 55011 class B (with external filter) EN 55032 class B (with external filter) FCC Part 18 class B (with external filter) EN 55011 class B (with external filter) EN 55032 class B (with external filter) FCC Part 18 class B (with external filter) www.tracopower.com/overview/tim2 EN 60601-1-2 edition 4 (Medical Devices) EN 61000-4-2, ±15 kV, perf. criteria A EN 61000-4-2, ±8 kV, perf. criteria A EN 61000-4-3, 10 V/m, perf. criteria A EN 61000-4-4, ±2 kV, perf. criteria A EN 61000-4-5, ±1 kV, perf. criteria A 9 Vin models: KY 1000 µF || TVS SMDJ18A 12 Vin models: KY 470 µF 24 Vin models: KY 470 µF 48 Vin models: KY 220 µF EN 61000-4-6, 10 Vrms, perf. criteria A EN 61000-4-8, 100 A/m, perf. criteria A EN 61000-4-8, 1000 A/m, perf. criteria A General Specifications Relative Humidity Temperature Ranges Power Derating Cooling System Remote Control - Operating Temperature - Case Temperature - Storage Temperature - High Temperature - Current Controlled Remote (passive = on) - Off Idle Input Current Altitude During Operation Regulator Topology Switching Frequency Insulation System Working Voltage (rated) Isolation Test Voltage Creepage Clearance Isolation Resistance - Input to Output, 60 s - Input to Output - Input to Output - Input to Output, 500 VDC 95% max. (non condensing) –40°C to +95°C +105°C max. –55°C to +125°C 6.67 %/K above 90°C See application note: www.tracopower.com/overview/tim2 Natural convection (20 LFM) On: open circuit Off: 2 to 4 mA current (internal 1 kΩ resistor) Refers to 'Remote' and '-Vin' Pin External circuit proposal: www.tracopower.com/info/current-remote.pdf 2.5 mA typ. 5'000 m max. Flyback Converter, RCC Converter 100 kHz min. (RCC) Reinforced Insulation 250 VAC 5'000 VAC 8 mm min. 8 mm min. 10'000 MΩ min. All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com November 15, 2023 Page 3 / 5 TIM 2 Series, 2 Watt Isolation Capacitance - Input to Output, 100 kHz, 1 V Leakage Current Reliability Washing Process - Touch Current - Calculated MTBF Environment - Vibration - Mechanical Shock - Thermal Shock Housing Material Base Material Potting Material Pin Material Pin Foundation Plating Pin Surface Plating Housing Type Mounting Type Connection Type Footprint Type Soldering Profile Weight Environmental Compliance - REACH Declaration - RoHS Declaration - SCIP Reference Number 16 pF typ. 20 pF max. 2 µA max. (at 240 VAC / 60 Hz) 6'809'000 h (MIL-HDBK-217F, ground benign) According to Cleaning Guideline www.tracopower.com/info/cleaning.pdf MIL-STD-810F MIL-STD-810F MIL-STD-810F Non-conductive Plastic (UL 94 V-0 rated) Non-conductive Plastic (UL 94 V-0 rated) Silicone (UL 94 V-0 rated) Copper Nickel (1 - 3 µm) Tin (7 - 12 µm), matte Plastic Case PCB Mount THD (Through-Hole Device) DIP16 Lead-Free Wave Soldering 260°C / 10 s max. 7g www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a, 7c-I (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule).) b0b10c00-0993-46b5-bf4c-c3885a5d658c Supporting Documents Overview Link (for additional Documents) www.tracopower.com/overview/tim2 All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com November 15, 2023 Page 4 / 5 TIM 2 Series, 2 Watt 3.2 14.4 (0.57) 10.16 (0.13) Outline Dimensions Pinout (0.400) 9 2.1 (0.08) Dual Output –Vin (GND) 2 Remote Remote 2 7 NC NC 8 NC Common 9 +Vout +Vout 10 –Vout –Vout +Vin (Vcc) +Vin (Vcc) 2.54 –Vin (GND) (0.100) 1 BOTTOM VIEW 10 Single Output 1 15.24 (0.600) 24.3 (0.96) 16 Pin 16 7 8 NC: Not connected Ø 0.60 (0.0024) Dimensions in mm (inch) Tolerances ±0.5 (±0.02) Pin Ø 0.6 ±0.1 (0.024 ±0.004) Pin pitch tolerances ±0.25 (±0.01) 3.8 (0.15) 10.2 (0.40) © Copyright 2023 Traco Electronic AG Specifications can be changed without notice. www.tracopower.com Rev. November 15, 2023 Page 5 / 5
TIM 2-2413 价格&库存

很抱歉,暂时无法提供与“TIM 2-2413”相匹配的价格&库存,您可以联系我们找货

免费人工找货
TIM 2-2413
    •  国内价格
    • 2+371.17289
    • 8+356.33539

    库存:0